Piston Cylinder Pressure & Diameter to Force Calculator

This tool will calculate the force generated by a piston cylinder for a specified pneumatic/hydraulic pressure and piston-cylinder bore diameter. Formula. The formula used by this calculator to determine the piston cylinder force from pressure and diameter is: r = ø/2. A = π·r 2 = π·(ø/2) 2. F = P·A. F = P·π·(ø/2) 2. Symbols. F

Learn More

how much natural gas shall be required to produce 1 ton of

How many m3 of Natural Gas required to make 1 to. To produce one ton of steam, You need 666000 kcal. To produce one ton of steam, and every one m3 of gas gives 9520 kcal. So, around 69 m3 of gas will produce 1 ton of steam. In case of fuel & air and no scales in the boiler. Also by increasing. [email protected] > Get A Quote >

Learn More

PDF THE INDIAN BOILERS ACT, 1923 - Bih

(ccc) "feed-pipe" means any pipe or connected fitting wholly or partly under pressure through which feed water passes directly to a boiler and which does not form an integral part thereof; * For Statement of Objects and Reasons, See Gazette of India, 1923, Pt. V, p. 249 and for Report of Joint Committee, see . ibid, p. 15.

Learn More

Hurst Boiler | Boiler Models| Plan Views | Spec Sheets

Hurst Boiler Literature Library. All documents available for download. HIGH PRESSURE BOILER with capacities from 20 to 2500 BHP. 670 to 83,688 MBTU/HR. Up to 86,250 PPH Steam. 2-pass scotch marine design with wetback construction Series 45 Specs Water 58 KB Series 45 Specs 39.42 KB Series 45 Specs Steam 59.5 KB Equipment Lifting Points

Learn More

How to calculate the kW required to heat a volume of water

The following formula is used to calculate the power of heating element needed to heat a specific volume of water by a given temperature rise in 1 hour. volume in litres x 4 x temperature rise in degrees centigrade / 3412 (4 being a factor and 3412 being a given constant)

Learn More

Chiller Tonnage Sizing & Capacity Calculator | Cold Shot

Oversize the chiller by 20% Ideal Size in Tons = Tons x 1.2; You have the ideal size for your needs; For example, what size chiller is required to cool 40GPM from 70°F to 58°F??T°F = 70°F - 58°F = 12°F; BTU/hr. = 40gpm x 60 x 8.33 x 12°F = 239,904 BTU/hr. Ton Capacity = 239,904 BTU/hr. ÷ 12,000 = 19.992 Tons

Learn More

How Power Plant Boiler Works? - Bright Hub Engineering

'Boiler feed water pump' pumps the water at high pressure into the boiler from the 'feed water tank'. The pump is akin to the heart in the human body. Pre-Heating 'Feed water heaters', using extracted steam from the turbine, adds a part of the sensible heat even before the water enters the boiler.

Learn More

PDF Pub. IG6-96 Energy and Cost Required to Lift or Pressurize

40 pounds per square inch pressure (psi). This requires energy and costs money. 1 psi pressure = 2.31 feet of water head The energy required to create a pressure of 43 psi is the same as the energy required to lift water 100 feet. Next to the last example: You have a drip system and are using ditch water that must be pressurized to 30 psi.

Learn More

How to Calculate Rectangular Water Tank Size & Capacity in

We all know Volume of water formula as 1 m 3 = 1000 litres of water. In order to get the size of the water tank, you need to mention at least one dimension (Length, Width or Depth of the water tank). If you are planning to construct a water tank in car parking area there may be some restriction on length.

Learn More

Steam Calculator: How To Calculate Steam Consumption

h fg: Enthalpy of evaporation or saturated enthalpy at operating pressure in kj /kg t: Time of warming-up in minutes Note: Suppose if the warm-up/heating time of the system is increased to 12 minutes from 6 minutes, then the initial flow rate of the steam can easily be reduced to half.

Learn More

Energy Required for Water Heating | EGEE 102: Energy

To calculate the heat required, determine the variables: m = mass of water heated = 700 gallons = 5810 lbs C p is the heat capacity of water = 1 BTU/lb ºF (given) ΔT = temperature difference = 120 ºF - 55 ºF. Heat energy required to heat 700 gal can be calculated as follows: Heat Required = 5810 lbs x 1 BTU/lb ºF x (120 ºF - 55 ºF)

Learn More

gas fired 1 ton steam boiler

The region above the county level cities and built-up area basically eliminated 10 tons of steam per hour coal-fired boilers and furnaces and tea, operating the stove, grain storage and drying equipment, coal-fired facilities, in principle, to a new 35 tons of steam per hour coal-fired boilers, in principle, to the rest of 10 tons of steam per

Learn More

LPG Gas Unit Conversion Values: kg, Litres, MJ, kWh & m³

A steady Pressure only shows that liquid LPG is inside the cylinder, and not how much liquid is left. In the US, pressure is measured in pounds per square inch (psi). Psi is defined as 1 pound of force applied per square inch. As a comparison, 1 psi = 6.89476 kPa. LPG Gas Unit Conversion Table: kg, Litres, MJ, kWh & m³

Learn More

PDF General Engineering Data - Complete Boiler Room Solutions

8" water 0.40" 33 74 148 327 508 1030 1680 3060 6410 11700 19000 38800 9" water 0.45" 35 79 158 347 540 1090 1780 3250 6810 12400 20200 41200 10" water 0.50" 37 83 166 366 569 1150 1880 3430 7180 13100 21300 43500 11" water 0.55" 38 87 175 385 598 1210 1980 3600 7550 13700 22300 45700

Learn More

how much kw is 1 ton boiler | CFBC BOILER MANUFACTURER

to freeze 1 short ton . how many kw equal 1.5 ton steam boiler BTU kcal h how much ton of steam boiler how many kw equal 1.5 ton steam boiler CONVERSION OF BOILER IN KG/H AND KW - CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP 1 kW = 860 kcal/h .

Learn More

Conversion unit, units, Flow rate, pressure, thermal

Pression (the unit of pressure of the S.I is the Pascal): The pressure is a force per unit of area. A Pascal corresponds to the pressure generated by a force of 1 Newton acting on a surface of 1 square meter also said Newton per square meter (N/m2).It is a rather small unit like result and it more often used as a kilopascal [ kPa ] or in bar, equivalent to 100 000 Pascal.

Learn More

Boiler Capacity - Engineering ToolBox

Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (h g - h f) m (1)

Learn More

Hot Water Pressure Increase in Hot Water Tanks or Boilers

Water is at its highest density at 3.98 °C = 1000 kg/m 3 or 1 g/cm 3. The correct SI unit of density of water is ρ = 1000 kg/m 3. [also FYI, 1 m 3 = 1,000,000 cm 3]; Specific weight of water = 62.4 lb/ft 3 (IU) or 9.81 kN/m 3; Specific weight of seawater = 64 lb/ft 3 (IU) or 10.1 kN/m 3 - must be all that extra salt making it more dense, so we float better in seawater than in fresh water, right?

Learn More

how much natural gas comsumed by boiler to produce 1 ton

How much natural gas is required to produce 1 ton of 930 cubic meter of natural gas. for a boiler to produce 1kg of steam is dependent on the size and how much steam produce 1 tonn water boiler how 1 Ton Steam Generation 3,210,000; Natural Gas mass) of steam. What is the fuel consumption of a 10,000#/hr steam boiler using 45.5 cu. ft

Learn More

BOILERS | Energy-Models.com

Fire tube or "fire in tube" boilers; contain long steel tubes through which the hot gasses from a furnace pass and around which the water to be converted to steam circulates. (Refer Figure 2.2). Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate, but they are limited generally to capacities of 25 tons/hr and pressures of 17.5 kg/cm 2.

Learn More

Energy Storage in Heated Water - kWh

c p = specific heat of water (kJ/kg o C, Btu/lb o F) (4.2 kJ/kg o C, 1 Btu/lb m o F for water) dt = temperature difference between the hot water and the surroundings (o C, o F)) m = mass of water (kg, lb m) Example - Energy stored in a 1000 liter water tank. Water is heated to 90 o C. The surrounding temperature (where the energy can be

Learn More

45 ton CFB boiler manufacture - hs-schauer.de

40 ton cfb high pressure boiler - CFBC Boiler Manufacturer. 40 tph water tube high pressure steam boiler - In the video, there are 40 ton, 45 ton, 50 25 ton CFB boiler for sale, CFB steam boiler for sugar mill, The 40 ton CFB power plant boiler is designed he told us he need a steam boiler applied in power station and the steam boiler

Learn More

How much steam does a liter of water produce - Answers

One liter of water weighs 1 kg so if it all turns to steam you will have 1 kg of steam. If the water is in an open container this will happen at 100 celsius. If it is in a closed container the

Learn More

Boiler Formulas - Johnston Boiler

Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / 34.5 Fe Factor of Evaporation BHP = 673 Cycle

Learn More

How to Convert GPM to Cooling Rate in Tons | Sciencing

How to Convert GPM to Cooling Rate in Tons. Factories use heat exchangers or chillers to regulate an area's temperature. The machine absorbs heat from an area that produces it and carries it to a different location. The medium that carries the heat is a refrigeration fluid that absorbs and releases heat as it

Learn More

How to Calculate Water Pump Horsepower: 14 Steps (with

Enter these values into the water horsepower formula. The water horsepower, or minimum power required to run the pump, equals ∗ ∗, where TDH is the total dynamic head in feet, Q is the flow rate in gpm, and SG is the specific gravity (1 for water). Enter all the values you found into this formula to find the water horsepower for your project.

Learn More

The Normal PSI Reading for a Hot Water Boiler System | Hunker

The standard cold water operating pressure of most U.S. and Canadian hot water boilers is 12 pounds per square inch (psi). If the boiler pressure drops below 12 psi, the valve will allow new water into the unit to bring up the pressure reading.

Learn More

PDF Rules and Regulations for Boiler and Pressure Vessel

RULES AND REGULATIONS FOR BOILER AND PRESSURE VESSEL INSPECTION (R.I.G.L. - 28-25) When a boiler and pressure vessel inspection law is at a pressure not exceeding l5 psi steam pressure or a hot water boiler in which water or other fluid is

Learn More

Converting Boiler steam rating from Kg/hr to Liters of

The boiler is a industrial steam boiler, which uses the steam for the process on site ( brewing boooz ) in this case in the past I have always been given the steam rating in LB/HR and have used the following; boiler capacity - 15000 lb.hr x 2 Devided by 10 x 4.54 = water capacity of 13620litres

Learn More

How to Calculate Water System BTU Measurements

Subtract the supply water temperature from the return water temperature to find the system temperature change. Calculate System Delivered BTU To find the system delivered BTU, multiply the BTU multiplier of 500 x the estimated Pump GPM x the System Temperature Change. Example: Say you calculate the pump pressure at 5.4 feet of head. Using the

Learn More

How to Calculate Boiler Steam Flows | Hunker

Use boiler horsepower to calculate steam flow. Boiler horsepower is not related to mechanical horsepower. It is a boiler industry rating that predicates the amount of saturated steam a boiler will generate starting with water at 212 degrees Fahrenheit and 0 pounds per square inch gauge (psig--meaning atmospheric pressure) and ending with steam at 212 F and 0 psig.

Learn More

How much gas does it take to heat water from 15 to 60

The amount of energy needed. From EnergyNumber's answer to the electricity version of this question:the energy needed is 180,000 x 45 x 4.2 = 34 MJ. 1kWh = 1000W x 3600s = 3.6 MJ. Hence, the energy needed is 34/3.6 = 9.5 kWh. Types of gas and units of measure. Two types of gas are typically used for heating and cooking purposes in homes:

Learn More

Steam Calculators: Boiler Calculator

Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.

Learn More

Water Calculator

The water calculator can even estimate how much water a child should drink. This is a sensible issue as a proper level of hydration helps the kid develop properly, maintain a healthy weight and good concentration levels.

Learn More

Convert metric tonnes of water to liters of water | water

This on the web one-way conversion tool converts water volume vs. weight units from metric tonnes of water ( t wt. ) into liters of water ( l ) instantly online. 1 metric tonne of water ( t wt. ) = 1,000.00 liters of water ( l ). How many liters of water ( l ) are in 1 metric tonne of water ( 1 t wt.

Learn More

PDF Steam Tables - Missouri

Pressure/Temperature Relationship (Columns 1, 2 and 3). For every pressure of pure steam there is a corresponding temperature. Example: The temperature of 250 psig pure steam is always 406°F. Heat of Saturated Liquid (Column 4). This is the amount of heat required to raise the temperature of a pound of water from 32°F to the boiling point at

Learn More

How much heat is required to make one kg of steam? - Quora

To answer this question we need to make several assmptions. 1. To make one kg of steam we need one kg of water. 2. Let water be at room temperature of say 20° C. 3. No loss of heat in heating the water from 20°C to its boiling point 100° C or conv

Learn More

how much water is required for producing 1 kilogram of

The mass won't change, so 1 kg of liquid water will form 1 kg of steam. Taking the density of water to be 1 g/cm³, you need 1 L of water to produce 1 kg of steam (in actual fact, you need a bit more, since water is not quite that dense). To make 1 ton of steam, assuming you use a metric ton, you need 1,000 L of water.

Learn More

Calculator: Saturated Steam Table by Pressure | TLV - A

Online calculator with Saturated Steam Table by Pressure. Includes 53 different calculations. Equations displayed for easy reference.

Learn More

Steam Capacity Conversion Table | Industrial Controls

Heating Water with Steam Example: How many lbs per hour of steam is need to heat 40 gallons per minute flow rate of water from 60 ° F to 180 ° F? Sizing a Boiler Feed Pump Receiver. The receiver tank should be able to hold five minutes worth of condensate for boilers up to 200 BHP and 10 minutes of condensate for boilers over 200 BHP.