High-pressure steam locomotive - Wikipedia

A high-pressure steam locomotive is a steam locomotive with a boiler that operates at pressures well above what would be considered normal. In the later years of steam, boiler pressures were typically 200 to 250 psi (1.38 to 1.72 MPa).High-pressure locomotives can be considered to start at 350 psi (2.41 MPa), when special construction techniques become necessary, but some had boilers that

Learn More

PDF Vertical FireTube Boilers

HURST PERFORMANCE SERIES BOILERS Skid Mounted Package Vertical FireTube Boilers High Pressure Design Capacities From 30 to 125 BHP. 1004 to 4184 MBTU/HR. Available in Steam & Hot Water Models Steam Pressures to 350 PSI. Hot Water Pressure 30-160 PSI Enhanced Fire Tubes Heat Transferring Spiral Surface. Compact FireTube Design All Steel

Learn More

ADOSH - Boiler Safety Section | Industrial Commission of

Heating or process boilers, not exceeding 15 psi (steam or vapor): A certificate inspection every two years. Hot-water boilers operating at pressures not exceeding 160 psi or a temperature not exceeding 250°F: An initial certificate inspection (may be external) with no further inspections required.

Learn More

Steam Gauge for sale | eBay

Make Offer - Vintage Marsh Steam Gauge Pressure 30 PSI Steampunk Industrial Vtg Copper Alloy ASHCROFT New York 8 1/2" Brass Steam Pressure Test Gauge REG US PAT OFF 56248027 $400.00

Learn More

PDF Steam Temperature Pressure Table

5 12.24 202.9 110 344.1 260 409.3 520 474 4 12.73 204.8 115 347.1 265 410.9 530 475.9 3 13.22 206.7 120 350 270 412.5 540 477.8 2 13.71 208.5 1 14.2 210.3 125 352.8 275 414.1 550 479.7 0 14.696 212 130 355.6 280 415.7 560 481.6 saturated steam temperatures pressure table steam temperature

Learn More

Boiler Material - IBLS

Nickel steel boilers were used on real locomotives thinking that the higher (70,000 psi) tensile strength would be an improvement over the standard 50,000 psi carbon steel. It worked for a while but due to the high amount of flexing from both firing and bouncing down a railroad track, these high strength, somewhat rigid steels began to crack

Learn More

Steam Calculators: Boiler Calculator - Energy.gov

Step 5: Determine Fuel Energy. Fuel Energy = Boiler Energy / Combustion Efficiency [ Fuel Energy = 153,936 = 131,000 / 0.851 ] Assumptions. Deaerator provides feedwater near the boiling temperature for the deaerator's set operating pressure. (Saturated Liquid) Steam, Boiler, and Blowdown Pressure are the same.

Learn More

Hurst | Cici Boiler Rooms

108500525 1-1/4″ x 1-1/4″ 150 PSI, Model 6010 108500480 1-1/4″ x 1-1/2″ 150 Cici Boiler Rooms is your source for Hurst boiler parts. We stock gaskets, handhole and manhole covers, low water cutouts, sight glass, valves, burner parts, and more. If you need burner parts, please obtain the information off your burner's tag as

Learn More

High Pressure Boilers 5th ed 3: exams 1-5, 12, 8

Watertube boilers were designed to operate at pressure as high as ___ psi, a point known as the critical pressure of steam. watertube A mud drum, if used, is the lowest part of the water side of a(n) ___ boiler.

Learn More

2.5 in. Tridicator/Boiler Temperature and Pressure Gauge

4.5 in. Dial 200 psi Stainless Steel Case Contractor Gauge: 2.5 in. Tridicator/Boiler Temperature and Pressure Gauge: 4 in. Stainless Steel Liquid Filled Case Pressure Gauge with 1/4 in. NPT Bottom Connection and Range of 0-100 psi/kPa: Price

Learn More

Boiler and Unfired Vessel Regulations

(i) For boilers or unfired pressure vessels in the field, 1.5 times the maximum allowable working pressure. (ii) For boilers of locomotives, 1.25 times the maximum allowable working pressure. (iii) For glass-lined unfired pressure vessels, the maximum allowable working pressure.

Learn More

PDF IMMERSION FIRED STEAM BOILER - Distillery Trail

250 14" 2 to 10 psi 10 psi 300-350 14" 1.5 to 10 psi 10 psi 400-800 1 psi 2 to 10 psi 10 psi steam boiler ratings, capacities, weights sea level to 3000 feet altitude boiler horse power hourly gas input (1000btu) gross hourly output (1000btu) pounds of steam per hour (1) normal water capacity (u.s. gal) flooded water weight (lbs) shipping

Learn More

PDF Part 14 Construction, Installation, Inspection and

inspection openings are opened or removed for inspection of the interior as required by the inspector. (w) Low pressure boiler means a steam boiler on which the safety valves are set at pressures not exceeding 15 psi. (x) Maximum allowable working pressure means the maximum gage pressure permissible at the top of a completed vessel in its operating position for a designated temperature.

Learn More

CleaverBrooks | CleanBoiler.org

o Steam boiler. o 10 to 60 HP. o Natural gas and propane. o 15 or 150 psi. o Standard < 20 ppm NOx , <10 ppm CO. Flexible Watertube. From 1.5 to 25.0 MMBTU/hr input for hot water and steam. Field-erectable packages also available. FLX - Flexible Watertube Boiler; o Steam or hot water. o 1.5 to 25.0 MMBTU

Learn More

Proper Pressure Settings for Residential Steam Boiler

The fact that your 0 to 5 psi gauge doesn't move, and the pressuretrol doesn't turn the boiler off, and the system heats well, simply indicates that your boiler is very well matched to your system. So be happy, don't worry.

Learn More

5 ton steam boiler need how much psi gas - CFBC Boiler

Steam Boilers & Appurtenances, Combustion & Instrumentation Controls, the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? Pumps, Water Heaters, Water Softeners, Boiler Seminars, Services & Parts. 5 How many inches of mercury are there at an atmospheric pressure of 14.5 psig?

Learn More

Coal boiler - All industrial manufacturers

Steam production: 3,450 lb/h - 60,000 lb/h Power: 3,400,000 BTU/h - 60,000,000 BTU/h Pressure: 100 psi - 900 psi. Hurst Boiler and Welding Co., Inc. provides its clients with the support and expertise necessary to design, fabricate and install complete coal fired boiler systems from the fuel storage

Learn More

CT Series Boilers: Efficient, Compact, Reliable High

Commercial, Industrial, & Waste Oil Boilers 610-323-2700 Residential Sales 610-473-8457

Learn More

PB Heat: Peerless® Boilers - America's BEST Built Boiler

Consumer Center It all begins with a Peerless ® boiler! Available from your local heating contractor, our boilers are the practical, efficient, clean alternative to furnaces and heat pumps.

Learn More

Industrial Steam Boiler for Sale | New & Used Boiler

New and Used Industrial Boilers for Sale Savona Equipment is an industrial steam boiler supplier worldwide. We sell steam boilers from 1.5 H.P. to 150 H.P. with pressures to 250 PSI capable of delivering dry steam in under 10 minutes. We can supply direct-fired hot water boilers which are available as gas, oil, propane, or combination-fired. Indirect-fired water heaters (available as gas or

Learn More

Boilers and Steam Generating Equipment

Subcritical, usually 1800 to 2600 psi (12.4 to 17.9 MPa) throttle pressure with 5% overpressure capability. Superheater and reheater outlet temperatures: As required, usually in the range of 1000 to 1050F (538 to 566C). Fuels: Natural gas and/or oil, blast furnace gas, and combustible byproduct gases. Radiant Boiler — El Paso Type RBE

Learn More

4 things to look out for in steam boiler pressure controls

For example, if a steam boiler had an additive differential pressure control and the setpoint was 3 psig and the differential was 2 psig, the boiler would cycle between 5 and 3 psi when there is a call for heat.

Learn More

Used Boiler Equipment Inventory

If you're in the market for used equipment then check out our used boiler equipment inventory. 425.774.6602 Ext. 6

Learn More

Boiler, 9.5 HP, Fulton, 100 PSI, Gas-fired, ICS 9.5-LE (7

Used 2005 Parker 9.5 HP boiler 100 PSI Steam Boiler 9.5 in San Diego, CA. Manufacturer: Parker; Complete steam system for sale. This includes Q=3 Parker 9.5 HP boilers, a duplex water softener system, feed water tank with preheat valve, blowdown tank, autoblow down controls and chemical injection pumps. P

Learn More

Chief Steamer 100 PSI Commercial Refill Steam Cleaner

A Chief Steamer cleaner has an "external" heat temperature sensor that is mounted on the bottom of the boiler to sense excessive temperature and turn the heater off if the temperature gets too hot. This saves the heater, the boiler, all components, and is an added safety feature. Chief Steamer cleaners all have 12 Gage wiring. These thicker

Learn More

High Pressure Steam Boilers (Over 15 PSI): steam boiler

Used Fulton ICS 9.5-LE Boiler with: 7 Available 9.5 HP Rated at 100 PSI Fue: Gas 328 LBS/HR Steam Fuel-fired steam boiler 399,000 Max BTU/HR input 13" max wc 2.4" Min WC Columbia CT Natural Gas Boiler 35 Horsepower

Learn More

Sellers Mfg - Boilers, Deaerators, Water Heaters, and

A very long life of Sellers boilers and heaters. Single Pass Design Even heating. No Turnaround chamber. A very long life of Sellers boilers and heaters. 0. Rapid Response Capacity Under 20 Minutes. 0. Higher System Efficiency - up to 40% Smaller Footprint. 0. Reduce Capital Expenditures, 90% Less Maintenance.

Learn More

0 to 5 psi Pressure and Vacuum Gauges - Grainger

0 to 5 psi Pressure and Vacuum Gauges. compressors, and regulators. Boiler gauges measure both the temperature and water pressure in boilers. Differential pressure gauges (analog and digital) measure and control pressure drops across filters, strainers, separators, valves, and pumps. 0 to 5 psi (0) Viewing as. List . Sort by

Learn More

150 HP Boiler Models | Cleaver-Brooks | York-Shipley

150 HP is a very commonly requested size in the boiler business. At 150 HP, you get maximum steam or hot water capacity with a minimally sized footprint, a low overall height for plants with overhead restrictions, and a variety of great American manufacturers who produce this size boiler. 150 HP boilers can be purchased in low pressure (15psi) steam, high pressure (150 - 300psi) steam, hot

Learn More

PDF Model H.E. Steam Boilers

Boilers operating 16 psi to 100 psi inclusive require a y-type gate or a ball valve rated for 125 WSP. Boilers operating 101 psi to 150 psi require piping designed for a pressure of 125% of the boiler safety valve set pressure (schedule 80 blowdown piping), one quick opening, and one slow opening blowdown valve. If

Learn More

MPH Series Boilers, The Brewers Choice Boiler by Columbia

MPH Series Boilers Low Pressure Steam Boilers Multi-Pass Horizontal Boilers. Competitively-priced, narrow in width, easily serviced, and fuel efficient, the MPH boiler is a modified Scotch, three-pass fire tube design.

Learn More

steam boiler 0 psi - la-oportunidad.com

Steam Boiler 0 Psi - wegwijsoverheidsopdrachten.be. Steam Boiler 0 Psi is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat

Learn More

Natural Gas 2psi or 5 psi???? - HVAC-Talk: Heating, Air

The tech i sent was able to find the numbers on the main regulator at the meter and according to the specs I found on it it's max output pressure is 2 psi. Problem solved! 01-13-2016, 12:20 PM #10

Learn More

PDF Bryan AB Series Steam & Hot Water Boilers Bryan "Flexible

All Bryan AB Series boilers offer these operating and performance features Guaranteed efficiency The breakthrough in water tube boiler design that pro-duced the AB Series provides operating efficiency so reliable, we guarantee it to be 83.5% for hot water boilers and 82% - 15 PSI / 80% - 150 PSI or better for steam. The Bryan Flexible Tube

Learn More

Blowdown Tanks & Blowdown Separators | Precision Boilers

Standard blowdown tank design pressure is 50 psi; the tank's vent is sized to limit the vessel pressure to 5 psi Boiler blowdown enters the vessel's lower-pressure environment, where approx. 30% flashes to steam, then flows out the tank's vent or can be piped so that its latent heat is recovered and used to preheat boiler feedwater

Learn More

Convert Ounce Per Square Inch to Psi (oz/in2 to psi

1 Ounce Per Square Inch to common pressure units; 1 oz/in2 = 430.92233 pascals (Pa) 1 oz/in2 = 0.0042528727362448 atmosphere atm standard (atm) 1 oz/in2 = 3.232192211338 millimeter of mercury (mmHg) 1 oz/in2 = 0.0043092233 bars (bar) 1 oz/in2 = 3.2321832795715 torrs (Torr) 1 oz/in2 = 6.2499999880344E-5 ksi (ksi) 1 oz/in2 = 0.062499999880344 psi (psi) 1 oz/in2 = 43.941848643523 kilogram force

Learn More

5 psi steam boiler pressure sensor with 1/4″ npt male

5 psi gauge pressure range, 4-20 milliamp current output pressure sensor for measuring the pressure in a steam boiler. This version of the IMP-LR low range pressure sensor has a 1/4 NPT male process connection with a built-in 150°C / 302°F cooling element for protecting the sensor and electronics from high temperature media such as steam.

Learn More

Boiler Hydrostatic testing procedure - Boilersinfo

This procedure defines the requirement and procedure of hydrostatic testing of the boiler pressure parts after completing the assembly of all the boiler high pressure and temperature components. Hydrostatic testing Objective Hydrostatic testing in the boiler is carried out to check the following: Leakages in the boiler pressure parts (Tubes, headers and Pipes).

Learn More

Boiler Test Flashcards - Flashcard Machine - Create, Study

The ASME Code will allow an automatic non-return valve to be used as a main steam stop valve. If one is used it must be: installed as close to the shell of the boiler as practical on the main steam line

Learn More

Vertical Hand-Fired Boiler | VHF Series | Hurst Boiler

The VHF Hybrid Boiler is available in 5 Base Model Choices: 50, 100,150, 200, 250 HP, in both Steam and Hot Water Systems with steam pressures of 15 PSI up to 150 PSI & 30 PSI Hot Water up to 60 PSI Hot Water. Units are available in both Vertical Hand Fired & Vertical Stoker Fired configurations.

Learn More